Main menu:
With exclusive CZ SINCRO database
• Internal Ah battery data base (ref.Yuasa) allows to test CCA (Cold Cranking Amps) and comparison with other makes.
• Tests batteries with liquid electrolyte or GEL, type: SLI, VRLA, SLA e AGM with flat or spiral plates for cars, trucks, boats, earthmoving machines, agricultural and industrial machines, equipped with batteries marked with CCA EN (European standard)
• Instruction Manual with conversion tables EN to SAE, DIN, IEC e JIS (Giappone) and operating messages on display drive the operator to measurements.
• Few seconds response for voltage state of charge (SOC) and residual capacity (state of health SOH) of 12 or 24 Volt (2 x 12 V in series) of conventional or sealed batteries, without disconnecting them from charging starting system.
Allows to foresee the replacing time.
• Does not discharge the battery with low residual capacity and does not develop sparks or heat during measurements.
MAIN TECHNICAL FEATURES
• Test batteries: 12 V
• Batteries capacity: 2 ÷ 30 Ah (motorcycles)
• Batteries CCA: 40 ÷ 2100 CCA (EN) (vehicles)
• CCA accuracy : ± 5%, resolution 1 A
• Voltage measurement: 1,5 ÷ 30 V (± 0.05 V)
• Operating temp.: 0 ÷ 50 °C
• Display: LCD, 2 x 16 characters
• Power supply: 9 Volt internal battery
• Dimensions: 17.5 x 9 x 4.5 cm
• Weight: 520 g
OPTIONS
• MM 2355 – Shockproof rubber holster.
• IM 0310 – Carrying case.